1 | Table | 1 | ||
Dimensions Table height Elevation range Elevation speed Movements Tilt angle Tilt speed Automatic stop |
: ±62 cm – 142 cm (24.4″ – 59.9″), elevating, motorized : ±80 cm (31.5″) : 2.5 cm/s (1″/s) : – 90° to + 90° : 2 speeds, 4.5°/s and 6.5°/s : In horizontal position |
|||
2 Table top | 1 | |||
Dimensions | ||||
Total dimensions | : ±73.8 cm x 235.6 cm (29″ x 92.8″) | |||
Radiolucent area | : ±221.4 cm x 55.4 cm (87.2″ x 21.8″) | |||
Table top to detector distance | : Min. 10.2 cm (4″) | |||
Material | : Micro sandwich of laminate, carbon and foam | |||
X-ray attenuation | : 0.6 mm (0.02″) Al (at 100 kVp, HVL = 2.7 mm (0.1″) Al) | |||
Maximum patient weight without limitations in movements | : ±284 kg (626 lbs) | |||
Movements | ||||
Lateral | : ± 32 cm (12.6″) = (± 16 cm (6.3″)) | |||
Longitudinal | : Only detector movements to improve patient comfort | |||
Movement speed | ||||
Lateral | : ±5 cm/s (1.9″/s), soft start and stop Auto centering | |||
Longitudinal | : Detector movement 3 cm/s – 20 cm/s (1.2″/s – 7.9″/s) | |||
Tube Column-detector Assembly | ||||
Movements | ||||
Range | : ±160 cm (63″) longitudinal, motorized | |||
Speed | : Variable, slow for positioning, high for travel maximum speed from 3 cm – 20 cm/s (1.2″/s – 7.9″/s) | |||
Patient coverage | : ±203 cm (79.9″), without patient movement | |||
Angulation | ||||
Movements | : Motorized | |||
Range | : ± 40° | |||
Speed | : ±11.2°/s | |||
Supporting functions | : Automatic centering of target organ during oblique projections in fluoroscopy | |||
: Oblique exposures at both ends of tabletop possible | ||||
Source image distance | ||||
Range | : ±113 cm – 183 cm (44″ – 72″) | |||
Movements | : Motorized | |||
Speed | : ±4.1 cm/s (1.6″/s) | |||
Focal spot to floor distance (in 90° position) | : ±51.5 cm – 211.5 cm (20.3″ – 83.3″) (without angulation) | |||
Tube rotation | : Manual | |||
Range | : – 90°/ + 180° | |||
Stop position | : – 90°/ – 50°/ – 40°/ 0°/ + 40°/ + 50°/ + 90°/ + 180° | |||
3 | 7 Amplimat chamber on the fluoroscopy table | Yes, this usefull for driving the x-ray beam with AEC for easy positioning patient and guaranty there have adequate: x-ray dose for better image quality | 1 | |
4 | Compressor | 1 | ||
Movements | : | Motorized | ||
Activation | : | Remote controlled | ||
Compression force | : | Variable, 3 kg – 15 kg (6.6 lbs – 33 lbs) in 0.5 kg (1.1 lbs) steps | ||
Compressor parking | : | Automatic, behind tube stand | ||
Cone | : Removable | |||
5 | Grid | : Stationary Grid | 2 | |
Material | : Carbon fiber | |||
Lines | : 44 lines/cm | |||
Focus (FO) | : ±120 cm (47.2″) and 180 cm (70.9″) | |||
Automatic selection of Grid according to SID and programmed examination plus motorized removal of grids. Fully | ||||
automatic, no grid handling necessary | ||||
6 | Single monitor trolley | : the trolley including 21.3″ medical monitor, articulated, height adjustable. | 1 | |
7 | Nearby control trolley | Trolley for in-room control of imaging and geometry parameters, including touchscreen geometry control console,: footswitch for fluoroscopy and exposure and sealed waterproof keyboard with touchpad. | 1 | |
8 | X-ray generation | 1 | ||
Exposure output power | : | 65 kW | ||
kV | : | 40 – 125 kV (dynamic exposures) | ||
mA range | : | 1 – 650 mA | ||
ms range | : | 1 ms – 4 s with AEC (Automatic Exposure Control) | ||
ms range | : 1 ms – 16 s without AEC | |||
Manual mode | ||||
Two-factor technique (kV – mAs) | : Yes | |||
Three-factor technique (kV – mA – s) | : Yes | |||
Automatic mode | ||||
One-factor falling load (kV) | : Yes | |||
Two-factor constant load (kV/mA) | : Yes | |||
Automatic kV reduction | : Yes | |||
IQX provides excellent, reliable and consistent image quality for digital exposures, both in static and dynamic | ||||
fluoroscopy studies. IQX controls and adapts the exposure parameters within the X-ray pulse. The automatic and | ||||
IQX Intelligent exposur | : | fast regulation of kV during each exposure leads to high image quality for all types of studies, for all patients. | ||
Control Fluoroscopy | : Yes | |||
9 | Tubes on Fluoroscopy table | : | 1 | |
Focal spot (small / large) | : 0.6 / 1.2 | |||
Min. anode speed | : up to 10K revolutions/minute | |||
Anode angle | : ±13° |
Maximum voltage | : | ±125 kV or (110 kV with GCF) | |
Nominal radiographic anode input power | : | ±30 kW / 85 kW | |
Double tube overload protection | : | Yes | |
Total filtration minimum | : | 2.5 mm AI (IEC 60522, 75 kV) | |
Compatible with pulsed fluoroscopy | : | Yes | |
Compatible with Controlled Fluoroscopy | : Yes | ||
10 Detectors (Fix on Fluoroscopy table) | 1 | ||
Electronic flat detector (CsI/Cesium Iodide) | : | Yes | |
Maximum field of view | : | ±43 cm x 43 cm (17″ x 17″) | |
Image matrix | : | ±2880 x 2881 pixels | |
Pixel size | : | 148 μm | |
Bit depth | : | 16 bits | |
DQE | : | 65 % at 0.1 lp/mm | |
MTF | : | 55 % at 1 lp/mm | |
Exposure dose | : | 0.1 – 10 μGy | |
Cooling | : | Automatic internal air cooling system | |
11 Automatic Image stitching on fluoroscopy table | : Yes | 1 | |
Capability doing Automatic image stitching, no need additional bucky stand but can using fluoroscopy table we call | |||
paralel stitching. As for standing (table tilt to standing 90 ° or patient or stitching in vertical posistion also laying | |||
: | down on the fluoroscopy table and the stitching in horizontal projection) | ||
12 Eleva workspot | 1 | ||
Processor Computer | : Based on Intel Core I7 | ||
Memory | : 16 GB RAM | ||
Local storage | : 1 TB Solid State Disk (SSD) | ||
Image review | |||
Dynamic unique for fluoroscopy and radiography | : Yes | ||
Multi image review | : Mosaic view of 4, 9 or 16 single images | ||
Zoom 1:1, 2:1, 3:3 | : Yes | ||
Monitors | |||
Two high quality color LCD monitors, one with touchscreen | : | Yes | |
Size | : | 21.3″ | |
DICOM calibrated for room environmental illuminance from 0 to 1000 LUX | : | Yes | |
DICOM illuminance compensation automatically adjusted for room illuminance | : | Yes | |
13 UNIQUE2 Dynamic UNIQUE | : Yes | 1 | |
2nd generation of post processing software that automatically adjust contras and enhance image detail, optiming | |||
image processing that reducing motion blur (leg effec) and optimaling image from the first frame so no initial dose | |||
needed. Adjust contras and minimizing noise. | |||
14 DICOM | 1 | ||
DICOM interoperability | : | Yes | |
DICOM Print for Rad images | : | Yes | |
DICOM store DICOM storage commit | : | Yes | |
DICOM worklist management | : | Yes | |
DICOM MPPS | : Yes | ||
15 Monitor to be placed in examination room | 1 | ||
Type | : | LCD color monitor IPS | |
Size | : | 21.3″ | |
Matrix | : | 1600″ x 1200″ (2 Megapixel) | |
Luminance ratio | : | > 800:1 | |
Dimensions | : | approx. 495 x 425 mm (19.5″ x 16.7″) | |
Weight | : | approx. 7.1 kg (15.6 lbs) | |
DICOM calibrated for room environmental illuminance from 0 to 1000 LUX | : | Yes | |
DICOM illuminance compensation automatically adjusted for room illuminance | : Yes | ||
Acessories | |||
16 Handgrips | : | Yes | 1 |
17 Shoulder support | : | Yes | 1 |
18 Side bar | : | Yes | 1 |
19 Pair of leg supports | : | Yes | 1 |
20 Dry Printer | : | Yes | 1 |
21 Panel & Cable | : | Yes | 1 |
22 UPS 3kVA | : | Yes | |
23 Warranty (year) | : Yes | 2 |