| No | Philips CombiDiagnost R90 HP with Dual Tube | Qty | |||
| 1 | Table | Description | 1 | ||
| Dimensions | |||||
| Table height | : 62 cm – 142 cm (24.4″ – 59.9″), elevating, motorized | ||||
| Elevation range | : 80 cm (31.5″) | ||||
| Elevation speed | : | 2.5 cm/s (1″/s) | |||
| Movements | |||||
| Tilt angle | : | – 90° to + 90° | |||
| Tilt speed | : | 2 speeds, 4.5°/s and 6.5°/s | |||
| Automatic stop | : In horizontal position | ||||
| 2 | Table top | 1 | |||
| Dimensions | |||||
| Total dimensions | : | ±73.8 cm x 235.6 cm (29″ x 92.8″) | |||
| Radiolucent area | : | ±221.4 cm x 55.4 cm (87.2″ x 21.8″) | |||
| Table top to detector distance | : | Min. 10.2 cm (4″) | |||
| Material | : | Micro sandwich of laminate, carbon and foam | |||
| X-ray attenuation | : | 0.6 mm (0.02″) Al (at 100 kVp, HVL = 2.7 mm (0.1″) Al) | |||
| Maximum patient weight without limitations in movements | : | ±284 kg (626 lbs) | |||
| Movements | |||||
| Lateral | : ± 32 cm (12.6″) = (± 16 cm (6.3″)) | ||||
| Longitudinal | : Only detector movements to improve patient comfort | ||||
| Movement speed | |||||
| Lateral | : ±5 cm/s (1.9″/s), soft start and stop Auto centering | ||||
| Longitudinal | : | Detector movement 3 cm/s – 20 cm/s (1.2″/s – 7.9″/s) | |||
| Tube Column-detector Assembly | |||||
| Movements | |||||
| Range | : ±160 cm (63″) longitudinal, motorized | ||||
| Speed | : Variable, slow for positioning, high for travel maximum speed from 3 cm – 20 cm/s (1.2″/s – 7.9″/s) | ||||
| Patient coverage | : ±203 cm (79.9″), without patient movement | ||||
| Angulation | |||||
| Movements | : | Motorized | |||
| Range | : | ± 40° | |||
| Speed | : | ±11.2°/s | |||
| Supporting functions | : | Automatic centering of target organ during oblique projections in fluoroscopy | |||
| : Oblique exposures at both ends of tabletop possible | |||||
| Source image distance | |||||
| Range | : | ±113 cm – 183 cm (44″ – 72″) | |||
| Movements | : | Motorized | |||
| Speed | : | ±4.1 cm/s (1.6″/s) | |||
| Focal spot to floor distance (in 90° position) | : | ±51.5 cm – 211.5 cm (20.3″ – 83.3″) (without angulation) | |||
| Tube rotation | : | Manual | |||
| Range | : | – 90°/ + 180° | |||
| Stop position | : – 90°/ – 50°/ – 40°/ 0°/ + 40°/ + 50°/ + 90°/ + 180° | ||||
| Yes, this usefull for driving the x-ray beam with AEC for easy positioning patient and guaranty there have adequate x-ray | |||||
| 3 | 7 Amplimat chamber on the fluoroscopy table | : | 1 | ||
| dose for better image quality | |||||
| 4 | Compressor | 1 | |||
| Movements | : | Motorized | |||
| Activation | : | Remote controlled | |||
| Compression force | : | Variable, 3 kg – 15 kg (6.6 lbs – 33 lbs) in 0.5 kg (1.1 lbs) steps | |||
| Compressor parking | : Automatic, behind tube stand | ||||
| Cone | : Removable | ||||
| 5 | Grid | : | Stationary Grid | 2 | |
| Material | : | Carbon fiber | |||
| Lines | : | 44 lines/cm | |||
| Focus (FO) | : | ±120 cm (47.2″) and 180 cm (70.9″) | |||
| Automatic selection of Grid according to SID and programmed examination plus motorized removal of grids. Fully | |||||
| Multi grid system | : | automatic, no grid handling necessary | |||
| Trolley for in-room control of imaging and geometry parameters, including touchscreen geometry control console, | |||||
| 6 | Nearby control trolley | : footswitch for fluoroscopy and exposure and sealed waterproof keyboard with touchpad. | 1 | ||
| 7 | X-ray generation | 1 | |||
| Exposure output power | : | 80 kW | |||
| kV | : | 40 – 150 kV (Second beam table and wall Bucky) | |||
| kV | : | 40 – 125 kV (dynamic exposures) | |||
| mA range | : | 1 – 1100 mA | |||
| ms range | : | 1 ms – 4 s with AEC (Automatic Exposure Control) | |||
| ms range | : 1 ms – 16 s without AEC | ||||
| Manual mode | |||||
| Two-factor technique (kV – mAs) | : Yes | ||||
| Three-factor technique (kV – mA – s) | : Yes | ||||
| Automatic mode | |||||
| One-factor falling load (kV) | : Yes | ||||
| Two-factor constant load (kV/mA) | : Yes | ||||
| Automatic kV reduction | : Yes | ||||
| IQX provides excellent, reliable and consistent image quality for digital exposures, both in static and dynamic fluoroscopy | |||||
| studies. IQX controls and adapts the exposure parameters within the X-ray pulse. The automatic and fast regulation of kV | |||||
| IQX Intelligent exposur | : | during each exposure leads to high image quality for all types of studies, for all patients. | |||
| 8 | Tubes on Fluoroscopy table | 1 | |||
| Dual Focal spot | : | Yes | |||
| Min. anode speed | : | up to 10K revolutions/minute | |||
| Anode angle | : | ≥12° | |||
| Maximum voltage | : | ±110 to 125 kV | |||
| Nominal anode input power | : | 44 kW / 64 kW | |||
| Double tube overload protection | : | Yes | |||
| Total filtration minimum | : | 2.5 mm AI (IEC 60522, 75 kV) | |||
| 9 | 2nd Tube | 1 | |||
| Dual Focal spot | : | Yes (0.6 / 1.2) | |||
| Min. anode speed | : | up to 10K revolutions/minute | |||
| Anode angle | : | ≥12° | |||
| Maximum voltage | : | 150 kV | |||
| Nominal anode input power | : | 44 kW / 64 kW | |||
| Double tube overload protection | : | Yes | |||
| 10 Eleva Tube Head | 1 | ||||
| Data displayed at the Eleva Tube Head | |||||
| Preview images | : | Yes | |||
| Grid status | : | Yes | |||
| Collimation field size | : | Yes | |||
| Angulation | : | Yes | |||
| Generator settings (kV, mA, mAs, AEC) | : | Yes | |||
| 11 Fix Vertical Stand | 1 | ||||
| Type | : | (VS) Fix Vertical Stand | |||
| Vertical travel | : | 35 cm to 185 cm, measured at center of detector | |||
| Automatic exposure control (AEC) | : | 5 AEC measuring fields | |||
| Operating | : | 2 user interfaces (left and right) and wireless remote control | |||
| Grips | : | Patient grips arranged on the left and the right of the detector unit | |||
| Brakes | : All movements are locked when system is switched off | ||||
| 12 Detectors (Fix on Fluoroscopy table) | 1 | ||||
| Electronic flat detector (CsI/Cesium Iodide) | : | Yes | |||
| Maximum field of view | : | 43 cm x 43 cm (17″ x 17″) | |||
| Image matrix | : | 2880 x 2881 pixels | |||
| Pixel size | : | 148 μm | |||
| Bit depth | : | 16 bits | |||
| Exposure dose | : | 0.1 – 10 μGy | |||
| Cooling | : | Automatic internal air cooling system | |||
| 13 SkyPlate (Wireless detector) | 1 | ||||
| Type | : | Wireless, Digital CsI (Cesium Iodide) flat detector | |||
| Housing material and Sensor protection material | : | Carbon fiber | |||
| Detector size | : | 35 cm x 43 cm (14″ x 17″) | |||
| Active area | : | 34.48 cm x 42.12 cm (13.6″ x 16.6″) | |||
| Image matrix size | : | 2,330 x 2,846 pixel | |||
| Pixel size | : | 148 μm | |||
| A/D Conversion (bits) | : | 16 bits | |||
| Weight (incl. battery) | : | 2.8 kg (6.2 lb) including battery | |||
| 100 kg (220 lb) on 4 cm disk for weight bearing examinations, 300 kg (662 lb) for distributed load, e. g. chest examinations | |||||
| Max. patient weight | : | ||||
| in bed | |||||
| Dust/water protection | : Yes | ||||
| 14 Stitching Function | : Yes | 1 | |||
| Capability doing Automatic image stitching, on the fluoroscopy table with paralel stitching technique. As for standing | |||||
| : (table tilt to standing 90 ° or patient stitching in vertical posistion also laying down on the fluoroscopy table and the | |||||
| stitching in horizontal projection) | |||||
| 15 Eleva workspot | 1 | ||||
| Processor Computer | : | Based on 3.9 GHz, Intel Core I7 | |||
| Memory | : | 16 GB RAM | |||
| Local storage | : | 1 TB Solid State Disk (SSD, 800 GB free for clinical images) | |||
| Dynamic unique for fluoroscopy and radiography | : | Yes | |||
| Multi image review | : | Mosaic view of 4, 9 or 16 single images | |||
| Zoom 1 : 1, 2 : 1, 3 :3 | : | Yes | |||
| Monitors | |||||
| Two high quality color LCD monitors, one with touchscreen | : Yes | ||||
| Size | : 21.3 inch | ||||
| 16 UNIQUE2 Dynamic UNIQUE | : Yes | 1 | |||
| 2nd generation of post processing software that automatically adjust contras and enhance image detail, optiming image | |||||
| processing that reducing motion blur (leg effec) and optimaling image from the first frame so no initial dose needed. | |||||
| Adjust contras and minimizing noise. | |||||
| 17 DICOM | 1 | ||||
| DICOM interoperability | : | Yes | |||
| DICOM Print for Rad images (SCU) | : | Yes | |||
| DICOM store (SCU) DICOM storage commit | : | Yes | |||
| DICOM worklist management (SCU) | : | Yes | |||
| DICOM MPPS (SCU) | : Yes | ||||
| DICOM structured dose report | : Yes | ||||
| 18 Monitor to be placed in examination room | 1 | ||||
| Type | : | LCD color monitor IPS | |||
| Size | : | 21.3″ | |||
| Matrix | : | 1600″ x 1200″ (2 Megapixel) | |||
| Luminance ratio | : | > 800:1 | |||
| Dimensions | : | approx. 495 x 425 mm (19.5″ x 16.7″) | |||
| Weight | : approx. 7.1 kg (15.6 lbs) | ||||
| Acessories | |||||
| 19 | 2nd WS (i7, 16GB DDR-2, 2TB, 27″ QHD) or Similar | : | Yes | 1 | |
| 20 | Handgrips | : | Yes | 1 | |
| 21 | Shoulder support | : | Yes | 1 | |
| 22 | Pair of leg supports | : | Yes | 1 | |
| 23 | Ceiling Construction | : | Yes | 1 | |
| 24 | Dry Printer | : | Yes | 1 | |
| 25 | Panel | : | Yes | 1 | |
| 26 | UPS 3kVA | : | Yes | 1 | |
| 27 | Apron | : | Yes | 1 | |
| 28 | Warranty (year) | : Yes | 3 | ||
- Beranda
- Imaging Systems
- Diagnost Radiography
- Philips CombiDiagnost R90 HP with Dual Tube
Philips CombiDiagnost R90 HP with Dual Tube
01 Overview
CombiDiagnost R90 is a remote controlled fluoroscopy system in combination with high-end digital radiography, designed to improve room utilization in a cost effective manner. A fully digital workflow, UNIQUE image quality and excellent dose management make the versatile system suitable for a wide range of examinations from pediatric to bariatric imaging.
Name: CombiDiagnost R90.
Brand: Philips
Certificate of Origin: Germany / Netherland
No. AKL: KEMENKES RI AKL 21501120698
- Price:
9.900.000.000,00
- E-Katalog LKPP Link: https://bit.ly/3VBJ3NQ
- Categories: Imaging Systems, Diagnost Radiography
- Share: