SPECIFICATION | ||
DATA SPESIFIKASI | ||
Software Specifications | ||
1 Concurrent user for Radiologist. | Yes | |
Unlimited concurrent user for clinicians | Yes | |
Support teleradiology | Yes | |
Reporting Module within PACS | Yes | |
Oracle 19c or equivalent enterprise database systems embedded to PACS server |
Yes | |
One desktop application featuring a PACS PowerViewer, 3D Basic processing, and web distribution |
Yes | |
Native 3D functionality tied into the workflow and embedded within the PACS |
Yes | |
Easy volumetric comparison of current and prior exams enabled by the PowerViewer, including an automatic registration algorithm and MPR display directly inside the viewer |
Yes | |
Easy-to-Use Bookmark tools, allowing marking, retrieving, viewing and over—time follow—up of findings in context of the entire exam |
Yes | |
Ability to support the following clinical features natively o MPR, MIP, 3D, Volume Rendering |
Yes | |
Hanging Protocols | Yes | |
o | Display Protocols serve to automatically control almost all aspects | |
of initial image display (layout, grouping, 3D views) | ||
o | Study type is customisable (modality, body part, imaging | |
procedure, number of images) | ||
o | Customisation is possible on site, group or individual basis | |
o | Display Protocols allow automatic loading of (relevant) patient | |
History and display for comparison | ||
o | The Vue PACS Client provides a comprehensive set of pre-defined | |
Display Protocols | ||
o | Image processing tools include: | Yes |
o | Interactive (mouse-activated) windowing | |
o | Automatic windowing | |
o | Modality-specific, user-adjustable window level pre-sets | |
o | Inverse windowing | |
o | Single image, group or all images windowing | |
o | Color maps – view in various colors besides grayscale, and other | |
dedicated color palettes for PET/CT reading | ||
o | Min/Max windowing method – provides an alternative image | |
windowing method based on min/max values (rather than | ||
centre/width) | ||
o | Interactive zoom and pan | |
o | Rotate and flip | |
o | Cine display mode with adjustable rate |
o o |
Edge enhancement Magnifying glass |
|
Reporting Module capabilities include: | Yes | |
o | Automatic template selection | |
o | Personalized templates & auto-texts | |
o | Continuous adaptation (vocabulary & recognition quality) | |
o | PACS Image/DICOM metadata may be included in the report | |
(technique, procedure code, structured reports) | ||
o | Support for multiple reports per study and for a single report | |
linked to several studies | ||
o | Batch Signing with Digital Signature | |
o | PACS generated data and measurements can be automatically | |
included in the report | ||
o | Key Images, Analysis reports, Bookmarking information may be | |
included in the report | ||
o | Modality SR data may be automatically inserted into the report | |
template | ||
o | HL7 HIS/RIS Interface for patient data and order information | |
VueMotion capabilities can support the main formats and related | Yes | |
functionalities | ||
o | DICOM Images Any non-proprietary SOP Class | |
o | DICOM Videos with DICOM MPEG formats | |
o | NON-DICOM Videos MPEG, MP4, AVI, MOV,VMW and other | |
standard containers | ||
o | NON-DICOM Documents PDF, CDA, DOC, PPT, TXT, XLS etc. | |
o | 3D VueMotion | |
Vendor Neutral Archive (VNA) include: | Yes | |
o | Single-point access to clinical images and other clinical data | |
including, images, video clips, waveforms and laboratory and | ||
biopsy results | ||
o | Access through a universal imaging viewer, a standards-based | |
DICOM Web browser or via existing EMR/HIS systems | ||
o | Web-based ingestion portal for importing any non-DICOM clinical | |
data into the PACS/VNA (DOC, PDF, CDA, WMV, AVI, MPEG) | ||
o | Imported non-DICOM clinical data available to add to an existing | |
study or as new study, merged to an existing order or a new one | ||
Integration | ||
o | Standard integration via DICOM 3.0 Protocols, HL7 and IHE profiles | |
o | Support API (COM), URL, Web Service and site specific ad hoc | Yes |
integration | ||
o | Support desktop integration, SSO (SAML 2.0), URL activation with | |
token and action button to launch 3rd party applications | ||
o | Seamless integration with advanced clinical applications such as | |
Philips IntelliSpace Portal | ||
Hardware Server Specification | ||
Server Rack/Tower | 1 unit | |
CPU minimum 8C or equivalent | Yes |
RAM minimum 64GB | Yes | |
Storage minimum 20TB | Yes | |
Client / Workstation Specification | 1 unit | |
CPU minimum 6C or equivalent | Yes | |
RAM minimum 16GB | Yes | |
Storage minimum 256 GB | Yes | |
OS Windows 10 Pro 64bit or latest | Yes | |
2MP Medical Monitor color single head | 1 unit | |
Implementation | Yes | |
o | Project Management | |
o | Installation | |
o | HIS integrations with HL7 (recommendations) | |
o | Super User Training | |
o | SIT and UAT | |
o | Go Live Support | |
o | 2 years warranty software support |