FEATURES & BENEFITS | ||
iDose4 | Improve spatial resolution and or reduction at low dose | |
OMAR | Improve image quality through artifact prevention and increased spatial resolution at low dose, | |
reduces artifacts caused by large orthopedic implants | ||
iPatient | System will automatically determine the optimal rotation time, pitch and collimation to deliver the | |
best result automatically | ||
Photo Realistic VR | Photo Realistic Volume Rendering (PRVR)is a post-processing technique, aimed to create realistic | |
3D images, making the image more “lifelike” than traditional image-rendering methods. | ||
Dose Management | DoseRight Index (DRI) | |
CT Dose Check | ||
DICOM structured reporting/IHE REM Profile | ||
DoseRight Automatic Currecnt Selection | ||
DoseRight Angular Dose Modulation | ||
DoseRight Z-DOM (longitudinal dose modulation) | ||
3D-DOM (combines angular and longitudinal info to modulate dose in 3D) | ||
Dedicated Pediatric Protocols | ||
Locking Protocols | ||
Dose Display and reports | ||
Dose Performance Data | ||
Spiral Auto Start | Spiral Auto Start allows the injector to communicate with the scanner. This allows the technologist | |
to monitor the contrast injection and to start the scan (with a predetermined delay) while in the | ||
scan room | ||
Comprehensive Cardiac Analysis | The Comprehensive Cardiac Analysis (CCA) application is designed to assist the user in viewing, | |
analyzing and quantifying dedicated Cardiac CT Angiograms, mainly for coronary arteries analysis | ||
on Coronaries CT Angiogram (CCTA) data. The application also offers cardiac function | ||
measurements. The application uses an automatic 3D model-based whole-heart segmentation to | ||
enable cardiac functional analysis. Analysis calculations include standard cardiac parameters such | ||
as EF, SV, CO, LV and RV mass, regurgitation volume and fraction index, RV/LV Early and Late filling | ||
volumes, and Early/Late LV filling ratio. The user has the ability to edit and modify the | ||
segmentation and the derived parameters. The application also enables automatic extraction and | ||
visualization of the coronary tree. If required, the user has the ability to edit these results. | ||
Key Benefits: | ||
• The application is designed to assist the user in viewing, analyzing and quantifying dedicated | ||
Cardiac CT Angiograms, mainly for coronary arteries analysis on Coronaries CT Angiogram (CCTA) | ||
data. | ||
• The application uses an automatic 3D model-based whole-heart segmentation to enable cardiac | ||
functional analysis. | ||
•Functional analysis of ventricles and valve morphology is done in 3D using dynamic cine mode. | ||
• Analysis calculations include standard cardiac parameters (e.g. EF, SV, CO, LV and RV mass, | ||
regurgitation volume and fraction index, RV/LV Early and Late (active and passive) filling volumes, | ||
and Early/Late LV filling ratio). | ||
• Enables automatic extraction and visualization of the coronary tree. If required, the user has the | ||
ability to edit these results. | ||
• The application labels the extracted coronary arteries, as a mean for results sharing. | ||
CT CCA now offers enhanced automatic extraction and visualization of the coronary tree, as well | ||
as enhanced automatic labeling of the different coronary segments. | ||
Calcium Scoring | The CT Calcium Scoring application features a one-click 3D segmentation and quantification for | |
coronary arteries calcifications including mass, Agatston, and volume scores. Calcium scoring is | ||
achieved by performing automatic calculations on CT Hounsfield Units in user-defined ROIs. The | ||
application supports ECG-gated and non ECG-gated images in DICOM format from Philips and | ||
other vendors but mass score can only be calculated for images acquired from Philips CT scanners. | ||
The application incorporates parameters from the MESA database. | ||
Key Benefits: | ||
• Supports the quantification of high-density structures such as calcified lesions in the cardio- | ||
thoracic region (e.g. coronary arteries, heart valves, aorta). | ||
• One-click 3D segmentation and quantification for coronary arteries calcifications (CAC) include | ||
mass, Agatston, and volume scores | ||
• Assessment of coronary artery calcium burden can be used as a prognostic indicator of the | ||
patient’s risk of morbidity/mortality from atherosclerotic coronary heart disease. | ||
• Calcium scoring is achieved by performing automatic calculations on CT Hounsfield units inside | ||
Regions-of-Interest (ROIs), which the operator manually places around selected areas within a | ||
sequence of images. | ||
• The application incorporates parameters from a large patient cohort with multislice CT calcium | ||
scores (Multi-Ethnic Study of Atherosclerosis, MESA database). | ||
• The application supports the creation of automated and customizable reports and distribute | ||
them electronically or on paper. | ||
Zero Click Performance | This option, also known as Enhanced Performance, is a powerful upgrade for IntelliSpace Portal | |
servers/ IX workstation which enables “zero-click” automated processing without any user | ||
interaction for the following clinical functions: | ||
• Automatic preprocessing of bone removal and vessel segmentation within the Advanced Vessel | ||
Analysis (AVA) application for CT angiography (CTA) cases | ||
• Automatic segmentation of cardiac anatomy within the Comprehensive Cardiac Analysis | ||
Reporting | aPrpopvliicdaetsi orneporting capabilities for dissemination of clinical results from the Portal including display | |
of key images and results frames. | ||
Key Benefits: | ||
• The report is available for referring physicians, patients, or for medical records. | ||
• Each report is editable and new default templates can be easily created and included in the | ||
system configuration. | ||
• The report can be saved as a PDF file for digital transfer or printed as a paper report. | ||
DETECTOR | ||
Slice Coverage | 64 Slice 40 mm | |
TUBE | ||
Anode Heat Capacity Maximum anode cooling rate Focal Spot | 8.0 MHU 1,608 kHU / min Small 0.5 x 1.0 ; Large 1.0 x 1.0 | |
GANTRY | ||
Rotation Time Aperture Gantry Tilt | 0.4, 0.5, 0.75, 1, 1.5 seconds for 360° scans ; 0.28, 0.33 seconds for partial angle 240° scans, effective cardiac rotation time 0.3 seconds 700 mm -30° to +30° with 0.5° increments | |
COUCH | ||
Maximum Scannable range | 1,750 mm | |
Pitch | 0.04 -1.5 | |
Longitudinal speed | 0.5 mm /s – 185 mm/s | |
Lowest table height | 579 mm | |
Maximum load capacity | 204 kg | |
GENERATOR | ||
Power Rating kVp setting mA range (step size) | 80 kW 80, 100, 120, 140 20 – 665 (1 mA steps) | |
IMAGE QUALITY | ||
Spatial resolution | Ultra high mode 24 lp/cm | |
RECONSTRUCTION | ||
Reconstruction Speed Standard Reconstruction Matrix Ultra High Reconstruction Matrix Iterative Reconstruction | 40 IPS 512 x 512 768 x 768 ; 1.024 x 1.204 iDose 4 Premium Package – improve image quality and metal artifact reduction | |
CONSOLE | ||
Operating System | Windows | |
Monitor | 2 x 19″ Monitor | |
Resolution | 1280 x 1024 | |
Remote control from console | Table : Up/Down, In/Out, Emergency stop, x-ray indicator, Start button, Pause button | |
DICOM | DICOM 3.0 compliant image format | |
ISP WORKSTATION | ||
Tipe | Stand Alone | |
Monitor | 2 x 24″ Monitor | |
Operating System | Windows | |
Advanced Softwares | Auto Cardiac segmentation | |
Globe View | ||
IVUS like View | ||
Easy Stenosis calculation | ||
Volume Rendering | ||
Coronary tree extraction | ||
Vessel visualization | ||
Slab tools (including cut planes) | ||
LV Functional Assessment | ||
Cine Mode | ||
ENd Systolic Volume (ESV) calculation | ||
End Diastolic Volume (EDV) calculation | ||
Cardiac Output | ||
Ejection Fraction (EF) | ||
Calcium Scoring | ||
Advanced Vessel Analysis | ||
Automatic Bone Removal | ||
Accessories & Support | ||
Dual Head Injector | Included | |
DICOM Printer | Included | |
Colour Paper Printer | Included | |
Lead Glass 100 x 120 | Included | |
UPS | Included | |
Service & Warranty | 3 (three) years | |
On-Site Training | 2 (two) times (Basic Training & Advanced Training) |
- Beranda
- E-Katalog
- Imaging Systems
- Computed Tomography
- Philips Ingenuity CT5000 64 with Photo Realistic VR
Philips Ingenuity CT5000 64 with Photo Realistic VR
01 Overview
The CT 5000 Ingenuity offers efficiency even in the most demanding environments, with advanced tools that streamline processes to enable consistency and reliability, day in and day out.
Name: Ingenuity CT5000 64 with Photo Realistic VR
Brand: Philips
Certificate of Origin: China
No. AKL: KEMENKES RI AKL 21501023919
- Price:
Rp.13.896.090.000,00
- E-Katalog LKPP Link: https://bit.ly/42tfQXu
- Categories: Imaging Systems, Computed Tomography
- Share:
02 Specification
03 All Computed Tomography Products
Philips Incisive CT Dual Energy AE with Advanced Visualization
Rp.18.300.000.000,00
Philips Incisive CT 128 Dual Energy AE with Advanced Visualization
Rp.18.300.000.000,00