Philips Ingenia Ambition Primary | |
DATA SPESIFIKASI | |
MAGNET | |
Magnet strength | 1.5 T |
Type of cryogen | Liquid Helium |
Vessel capacity | 7 Liters |
Cooling technology | Micro-cooling technology – highly-efficient micro-tubes using 7 liters of liquid helium |
Cryogen boil-off rate | Not applicable, fully sealed |
Cryogen refill Interval | Not applicable, fully sealed |
Diameter lubang magnet | 70 cm |
Magnet Length | 1.62 m |
Type Magnet | Superconductor |
RF Receive | DirectDigital technology that samples the MR signal directly in the RF coil on the patient. The fiber-optic transmission of digital broadband data from the coil to the image reconstructor removes potential noise influences typical with analog pathways. |
Maksimum FOV in X &Y directions | 55 cm |
Number of receive channels | Independent Channel / digital broadband system |
Dicom package | Include |
GRADIENT | |
Gradient Amplitude | 33 mT/m |
Gradient Slew Rate | 120 T/m/s |
RF RECEIVE | |
Number of independent receive channels | Channel independent |
Signal chain from coil to reconstructor | Fully digital |
Location of analog-to-digital converter (ADC) | Inside the coil close the receive channels |
Signal chain from coil electronics to connector | Digital |
Signal chain from connector to magnet | Digital |
Signal chain from magnet to reconstructor | Digital |
COIL | |
Coil for Head | Head coil |
Coil for Spine | Spine Coil |
Coil for Abdomen | Torso Coil |
Coil for Shoulder | Shoulder Coil |
Coil for Knee | Knee Coil |
PATIENT ENVIRONMENT | |
Choice of head-first or feet-first patient | Yes |
Horizontal travel distance | 275 cm |
Maximum weight capacity | 250 kg |
Integrated Spine Coil on the table | Yes |
Ambient Lighting on Gantry | Ambient Ring standard |
In-bore lighting | On/Off |
fresh air supply | 6 levels |
Patient communication | Intercom from magnet tunnel to operator |
Acoustic noise reduction software | Autosoftone noise reduction |
SOFTWARE CAPABILITIES on SCANNER | |
AutoVoice | With AutoVoice the patient is guided through the MR examination with voice audio information to the patient on length of scan, breath hold and table movement. Multiple languages can be selected. Includes a recording option for specific commands or languages |
ComforTone is a scan technique that brings noise reduction. ComforTone ExamCards | |
ComforTone | will be available for routine exams |
(Brain, Spine, MSK) including the reference scans | |
ScanWise Implant is a user interface with guidance that simplifies scanning patient | |
with MR Conditional implants. It allows you to enter the implant’s MR Conditional | |
values only once and as specified by the implant manufacturer. It will automatically | |
ScanWise Implant | adjust all scan and pre-scan parameters to meet the implant conditional values |
entered by the operator. ScanWise implant makes your MR scanner adhere to the | |
entered implant conditions throughout | |
the whole examination | |
Software Kepala dan Spine | |
Sequences include SE, FFE and EPI based methods, with fat suppression methods including STIR, SPIR, ProSet and SPAIR, FLAIR for CSF Suppression | |
VISTA : isotropic 3D TSE for volumetric acquisitions with reconstruction in any plane | |
3D T1-TFE sequences for volumetric acquisition and reconstruction of the original dataset in any orientation | |
3D TFE for isotropic coverage of the entire head in short scantimes using SENSE | |
DRIVE : for T2-weighted 2D and 3D TSE acquisitions, used to improve fluid visualization (IAC), for short scan times and to increase resolution. | |
Balanced FFE/TFE for high-resolution high contrast (IAC and Spine applications) | |
Single-shot EPI diffusion-weighted imaging (DWI) with three diffusion directions and up to 16 b-values, robust against motion and generating isotropic DWI images |
|
BolusTrak enables accurate synchronization of high-resolution CE-MRA acquisitions uses a real-time fluoroscopic display of bolus arrival. | |
TRACS enables accelerated time-resolved contrast-enhanced vascular imaging. TRACS uses SENSE for image acceleration and CENTRA phase-encode ordering for optimized contrast. |
|
m-FFE provides unique image contrast – ranging from 2D or 3D gradient-echo sequences to the combination of echoes | |
Venous BOLD provides T2*-weighted 3D sequences compatible with SENSE. These sequences are useful for evaluating various brain anomalies associated with venous blood |
|
Phase contrast (PC) sensitive imaging for the visualization of moving fluids. | |
MobiFlex and MobiView, compatible with all sequences, for easy Total Spine imaging | |
T2* perfusion analysis. | |
1 |
SmartExam Brain enables automatic planning of head examinations for consistent head studies with optimized scan quality, independent of patient, patient | |
positioning or operator | |
SmartExam Spine, for spine examinations with automated numbering of the vertebrae. Includes a snapping mechanism, which allows easy definition of the levels for transverse stacks. Dragging a stack from one level to another makes the stack snap accurately to the next spinal disc level. |
|
Spectroscopy Specialist : includes a complete set of single voxel, multi-voxel and multi-slice proton spectroscopy acquisition methods executed by ExamCards and Includes the SpectroView Analysis package for visualization and processing of all spectroscopic data. |
|
Single, Dual and Triple IR sequences for evaluation of gray and white matter differentiation. | |
2D TSE with Flip Angle Sweep technology for SAR and Magnetization Transfer reduction, improving gray/white matter contrast in both T2 and FLAIR | |
Multiple radial projection myelography both with 2D and 3D sequences. | |
Software Muskuloskeletal | |
SE, TSE, and FFE sequences, with fat suppression provided by STIR, ProSet, SPIR and adjustable fat suppression with the SPAIR method. | |
Balanced acquisitions (bFFE) for high-resolution morphology scans | |
DRIVE combined with TSE to increase sensitivity to fluids (with good T2 weighting), even with short TRs | |
Turbo-STIR for fat-suppressed evaluation of bone bruises | |
TSE with asymmetric profile ordering for proton density weighted imaging of joints with higher spatial resolution or faster scan times. | |
e-THRIVE for 3D high-resolution fat-suppressed imaging for MR arthrograms | |
MobiFlex for simple visualization of total spine imaging and multiple-station | |
Dynamic imaging sequences for TMJ or other joint studies. | |
Software Thorax dan Abdomen | |
TSE sequences with respiratory triggering (in combination with breath hold or free breathing). | |
In and out of phase FFE/TFE sequences. | |
SPAIR for high uniformity fat saturation. | |
e-THRIVE volumetric imaging with fat suppression, in short breath-hold times Keyhole for high temporal dynamic imaging. | |
Diffusion-weighted sequences with automated creation of Apparent Diffusion Coefficient (ADC) maps. | |
MRCP sequences, (radial) single shot and 3D acquisitions. | |
MobiView and MobiFlex for automatic composition of data sets from multi- station acquisitions into full FOV images. | |
Dynamic scan techniques for monitoring and evaluation of contrast uptake viewing. | |
High Resolution Diffusion / DWIBS package enables single or multi-station high resolution diffusion weighted imaging with background suppression. Patient and physiological motion is controlled by navigator-based motion correction. |
|
Real-time respiratory navigator to synchronize data acquisition to the respiratory cycle of the patient. | |
Software Breast | |
SPAIR for high uniformity fat saturation. | |
e-THRIVE for volumetric coverage with uniform fat suppression. | |
BLISS, two bilateral sagittal volumes within a single acquisition. | |
Diffusion-weighted sequences with automated creation of Apparent Diffusion. | |
Silicone-Only sequences optimized for breast implants. | |
Software Cardiac dan Vascular | |
Black blood prepulses to suppress blood signal for optimized myocardial and lumen visualization. | |
Multi Slice / Multi Phase for function studies. | |
Retrospective triggering with real-time prospective updating for full R-to-R coverage of function studies. | |
Temporal profile sharing for playback frame rates higher than acquisition frame rates. | |
VCG gating for robust ECG gating and triggering (includes a four-lead cable set). | |
ECG-triggered STIR (inversion recovery TSE) including black blood imaging | |
ECG-triggered Inversion Recovery (including PSIR) for myocardial tissue characterization | |
Non-invasive quantitative flow measurements of blood, including overlaid colorencoded flow maps on the console | |
2D/3D Balanced TFE/FFE for fast, high-resolution non-contrast enhanced vascular imaging. | |
Phase-Contrast Angio for imaging of brain vasculature | |
TRANCE for 3D high contrast TSE acquisitions without vascular contrast agents | |
Time-of-flight (inflow) sequences with TONE to improve contrast and MTC to reduce peri-orbital fat signal | |
Acessories & Support | |
Workstation | Included |
Garansi unit MRI | 5 Tahun |
Garansi Helium | Lifetime |
On-Site training | 3 kali (Basic, Intermediate & Advanced) @ 5 hari |
Water Chillers | Included |
AC MRI | Included |
RF Cage/Shielding | Included |
MR Injector | Included |
UPS | Included |
Printer | Included |
Cable Tray | Included |
Wheelchair | Included |
Audio System for patient convenience | Included |
Metal Detector | Included (Handheld Metal Detector) |
Monitor tanda vital | Included |
Non Magnetic IV Pole | Included |
2 |