TUBE | ||
Anode Heat Capacity Maximum anode cooling rate Focal Spot | 8.0 MHU 1,608 kHU / min Small 0.5 x 1.0 ; Large 1.0 x 1.0 | |
GANTRY | ||
Rotation Time Aperture / Bore Diameter True Scan Field of View Extended Scan Field of View Gantry Tilt | 0.44, 0.5, 0.75, 1.0, 1.5 and 2.0 seconds for 360° scans ; 850 mm 600 mm 700 mm -30° to +30° with 0.5° increments | |
COUCH | ||
Maximum Scannable range helical Pitch Movement table range Maximum load capacity | 1,730 mm 0.04 -1.65 579 – 1019 mm 295 kg | |
GENERATOR | ||
Power Rating kVp setting mA range (step size) | 80 kW 80, 100, 120, 140 20 – 665 (1 mA steps) | |
DETECTOR | ||
Slice Coverage | 32 Slice 24 mm | |
RECONSTRUCTION | ||
Standard Reconstruction Matrix Ultra High Reconstruction Matrix Iterative Reconstruction | 512 x 512 768 x 768 ; 1.024 x 1.024 iDose 4 Premium Package – improve image quality and metal artifact reduction | |
CLINICAL ENHANCEMENTS | ||
iDose4 | Improve spatial resolution and or reduction at low dose | |
OMAR | Improve image quality through artifact prevention and increased spatial resolution at low dose, | |
reduces artifacts caused by large orthopedic implants | ||
iPatient | System will automatically determine the optimal rotation time, pitch and collimation to deliver | |
the best result automatically | ||
Dose Management | Automatic Current Selection (ACS) | |
Dynamic Dose Modulation (DDOM) | ||
z-axis Dose Modulation (zDOM) | ||
Dedicated Pedatric Protocols | ||
Display of CTDIvol and DLP during planning | ||
Pulmonary Toolkit for Onco with Amp Bin | Philips Pulmonary Toolkit for Oncology w/Amp Bin includes the features found in the Philips | |
Pulmonary Toolkit, and also includes retrospective spiral (4D CT) capabilities. This also provides | ||
two methods for binning 4D CT data – phase only, or amplitude with phase. | ||
Virtual Simulation | provides accurate and efficient workflow in imaging simulation by enabling scan-to-plan | |
functionality directly at the scanner console. This application provides tools to assist in patient | ||
marking and virtual simulation for radiation therapy planning, including isocenter localization, | ||
contouring, creating beam arrangements, generating MLCs and blocks, and setting machine | ||
definitions | ||
ACCESSORIES & SUPPORT | ||
Single Head Injector | included | |
DICOM Printer | included | |
Lead Glass 100 x 120 cm | included | |
Laser Positioning | included | |
Electron Density Phantom | included | |
UPS | included | |
Service & Warranty | 3 (three) years for Main Equipment | |
On-Site Training | 2 (two) times (Basic Training & Advanced Training) |
- Beranda
- E-Katalog
- Imaging Systems
- Computed Tomography
- Philips CT Big Bore 32 with Laser Positioning
Philips CT Big Bore 32 with Laser Positioning
01 Overview
CT scanner and simulator designed for radiation oncology and therapy. Big Bore RT is designed as a CT simulator to enhance clinical confidence, accelerate time to treat and maximize value of its investment without compromising on patient experience – four dimensions that are essential towards excellent care.
Name: CT Big Bore 32 with Laser Positioning
Brand: Philips
Certificate of Origin: China
No. AKL: KEMENKES RI AKL 21501023227
- Price:
Rp.17.013.000.000,00
- E-Katalog LKPP Link: https://bit.ly/3VvY6st
- Categories: Imaging Systems, Computed Tomography
- Share:
02 Specification
03 All Computed Tomography Products
Philips Incisive CT Dual Energy AE with Advanced Visualization
Rp.18.300.000.000,00
Philips Incisive CT 128 Dual Energy AE with Advanced Visualization
Rp.18.300.000.000,00