TUBE | ||
Anode Heat Capacity Maximum anode cooling rate Focal Spot Anode rotation speed |
8.0 MHU 1,608 kHU / min Small 0.5 x 1.0 ; Large 1.0 x 1.0 105 Hz (6,300 rpm) |
|
GANTRY | ||
Rotation Time | 0.44, 0.5, 0.75, 1.0, 1.5 and 2.0 seconds for 360° scans ; | |
Aperture / Bore Diameter | 850 mm | |
True Scan Field of View | 600 mm | |
Extended Scan Field of View | 700 mm | |
Gantry Tilt | -30° to +30° with 0.5° increments | |
COUCH | ||
Maximum Scannable range helical | 1,730 mm | |
Pitch | 0.04 -1.65 | |
Longitudinal speed | 0.5 mm /s – 185 mm/s | |
Movement table range | 579 – 1019 mm | |
Maximum load capacity | 295 kg | |
GENERATOR | ||
Power Rating kVp setting mA range (step size) |
80 kW 80, 100, 120, 140 20 – 665 (1 mA steps) |
|
DETECTOR | ||
Slice Coverage |
16 Slice 24 mm |
|
IMAGE QUALITY | ||
Spatial resolution Low contrast resolution Image noise Absorption range |
16 lp/cm 4.0 mm @ 0.3% @ 14.1 mGy CTDIvol 0.27% ± 0.04% at 120 kV, 250 mAs, 12 mm slice thickness -1,024 to +3,071 Hounsfield units |
|
RECONSTRUCTION | ||
Reconstruction speed Standard Reconstruction Matrix Ultra High Reconstruction Matrix Iterative Reconstruction |
up to 30 IPS 512 x 512 768 x 768 ; 1.024 x 1.204 iDose 4 Premium Package – improve image quality and metal artifact reduction |
|
CLINICAL ENHANCEMENTS | ||
iDose4 | Improve spatial resolution and or reduction at low dose | |
OMAR | Improve image quality through artifact prevention and increased spatial resolution at low dose, | |
reduces artifacts caused by large orthopedic implants | ||
iPatient | System will automatically determine the optimal rotation time, pitch and collimation to deliver | |
the best result automatically | ||
Dose Management | Automatic Current Selection (ACS) | |
Dynamic Dose Modulation (DDOM) | ||
z-axis Dose Modulation (zDOM) | ||
Dedicated Pedatric Protocols | ||
Display of CTDIvol and DLP during planning | ||
Pulmonary Toolkit for Onco with Amp Bin | Philips Pulmonary Toolkit for Oncology w/Amp Bin includes the features found in the Philips | |
Pulmonary Toolkit, and also includes retrospective spiral (4D CT) capabilities. This also provides | ||
two methods for binning 4D CT data – phase only, or amplitude with phase. | ||
TumorLOC | Tumor LOC provides accurate and efficient workflow in imaging simulation by enabling scan-to- | |
plan functionality directly at the scanner console. This application provides tools to assist in | ||
patient marking and virtual simulation for radiation therapy planning, including isocenter | ||
localization, contouring, creating beam arrangements, generating MLCs and blocks, and | ||
setting machine definitions | ||
WORKSTATION | ||
Tipe | Stand Alone | |
Monitor | 24″ Monitor | |
ACCESSORIES & SUPPORT | ||
Injector | included | |
DICOM Printer | included | |
Lead Glass 100 x 120 cm | included | |
UPS | included | |
Service & Warranty | 2 (two) years | |
On-Site Training | 2 (two) times (Basic Training & Advanced Training) |
- Beranda
- E-Katalog
- Imaging Systems
- Computed Tomography
- Philips Brilliance CT Big Bore
Philips Brilliance CT Big Bore
01 Overview
CT scanner and simulator designed for radiation oncology and therapy. Big Bore RT is designed as a CT simulator to enhance clinical confidence, accelerate time to treat and maximize value of its investment without compromising on patient experience – four dimensions that are essential towards excellent care.
Name: Brilliance CT Big Bore
Brand: Philips
Certificate of Origin: China
No. AKL: KEMENKES RI AKL 21501515381
- Price:
Rp.12.978.030.000,00
- E-Katalog LKPP Link:https://s.id/1VvmM
- Categories: Imaging Systems, Computed Tomography
- Share:
02 Specification
03 All Computed Tomography Products
Philips Incisive CT Dual Energy AE with Advanced Visualization
Rp.18.300.000.000,00
Philips Incisive CT 128 Dual Energy AE with Advanced Visualization
Rp.18.300.000.000,00