| TUBE | ||
| Anode Heat Capacity Maximum anode cooling rate Focal Spot Anode rotation speed |
8.0 MHU 1,608 kHU / min Small 0.5 x 1.0 ; Large 1.0 x 1.0 105 Hz (6,300 rpm) |
|
| GANTRY | ||
| Rotation Time | 0.44, 0.5, 0.75, 1.0, 1.5 and 2.0 seconds for 360° scans ; | |
| Aperture / Bore Diameter | 850 mm | |
| True Scan Field of View | 600 mm | |
| Extended Scan Field of View | 700 mm | |
| Gantry Tilt | -30° to +30° with 0.5° increments | |
| COUCH | ||
| Maximum Scannable range helical | 1,730 mm | |
| Pitch | 0.04 -1.65 | |
| Longitudinal speed | 0.5 mm /s – 185 mm/s | |
| Movement table range | 579 – 1019 mm | |
| Maximum load capacity | 295 kg | |
| GENERATOR | ||
| Power Rating kVp setting mA range (step size) |
80 kW 80, 100, 120, 140 20 – 665 (1 mA steps) |
|
| DETECTOR | ||
| Slice Coverage |
16 Slice 24 mm |
|
| IMAGE QUALITY | ||
| Spatial resolution Low contrast resolution Image noise Absorption range |
16 lp/cm 4.0 mm @ 0.3% @ 14.1 mGy CTDIvol 0.27% ± 0.04% at 120 kV, 250 mAs, 12 mm slice thickness -1,024 to +3,071 Hounsfield units |
|
| RECONSTRUCTION | ||
| Reconstruction speed Standard Reconstruction Matrix Ultra High Reconstruction Matrix Iterative Reconstruction |
up to 30 IPS 512 x 512 768 x 768 ; 1.024 x 1.204 iDose 4 Premium Package – improve image quality and metal artifact reduction |
|
| CLINICAL ENHANCEMENTS | ||
| iDose4 | Improve spatial resolution and or reduction at low dose | |
| OMAR | Improve image quality through artifact prevention and increased spatial resolution at low dose, | |
| reduces artifacts caused by large orthopedic implants | ||
| iPatient | System will automatically determine the optimal rotation time, pitch and collimation to deliver | |
| the best result automatically | ||
| Dose Management | Automatic Current Selection (ACS) | |
| Dynamic Dose Modulation (DDOM) | ||
| z-axis Dose Modulation (zDOM) | ||
| Dedicated Pedatric Protocols | ||
| Display of CTDIvol and DLP during planning | ||
| Pulmonary Toolkit for Onco with Amp Bin | Philips Pulmonary Toolkit for Oncology w/Amp Bin includes the features found in the Philips | |
| Pulmonary Toolkit, and also includes retrospective spiral (4D CT) capabilities. This also provides | ||
| two methods for binning 4D CT data – phase only, or amplitude with phase. | ||
| TumorLOC | Tumor LOC provides accurate and efficient workflow in imaging simulation by enabling scan-to- | |
| plan functionality directly at the scanner console. This application provides tools to assist in | ||
| patient marking and virtual simulation for radiation therapy planning, including isocenter | ||
| localization, contouring, creating beam arrangements, generating MLCs and blocks, and | ||
| setting machine definitions | ||
| WORKSTATION | ||
| Tipe | Stand Alone | |
| Monitor | 24″ Monitor | |
| ACCESSORIES & SUPPORT | ||
| Injector | included | |
| DICOM Printer | included | |
| Lead Glass 100 x 120 cm | included | |
| UPS | included | |
| Service & Warranty | 2 (two) years | |
| On-Site Training | 2 (two) times (Basic Training & Advanced Training) | |
- Beranda
- Imaging Systems
- Computed Tomography
- Philips Brilliance CT Big Bore
Philips Brilliance CT Big Bore
01 Overview
CT scanner and simulator designed for radiation oncology and therapy. Big Bore RT is designed as a CT simulator to enhance clinical confidence, accelerate time to treat and maximize value of its investment without compromising on patient experience – four dimensions that are essential towards excellent care.
Name: Brilliance CT Big Bore
Brand: Philips
Certificate of Origin: China
No. AKL: KEMENKES RI AKL 21501515381